.nr H1 3 .H 1 "Bug Fixes" .\" .\"What bugs have been fixed in since its last release? .\" This chapter lists the bug fixes in Disk Plexing Option since the last release (IRIX 6.2). Some descriptions include a Silicon Graphics bug report number in the form \f2XXXX\f1 or \f2XXXXXX\f1. .BL .LI xlv_labd(1m) is automatically started if a plex revive request is issued and the xlv_labd does not exist. .LI Losing a disk drive that is part of a root volume can sometimes cause the system to hang. (bug #392195) .LI A plexed root drive could be corrupted if one plex was detached/attached, and the system was then cleanly shutdown and rebooted. (bug #422798) .LI Xlv_mgr(1m) core dumps detaching a NULL volume element from a standalone plex. (bug #426966) .LI Only mark the target disk online after a revive if no errors occured. .LI Xlv_assemble(1m) won't gratuitously initiate a plex revive for a triple-plexed volume element when the volume element was cleanly shutdown. (bug #341023) .LI Xlv_mgr(1m) "detach" command has a new -force option so a missing plex or volume element can be removed. This allows broken disks to be easily replaced. .LI Xlv_mgr(1m) "show kernel" command displays plex revive progress. The mapping of the subvolume open_flag value has been corrected. A volume name can be specified so that only information pertaining to that kernel volume is displayed. .LI Fixes a kernel panic if plexing software is not installed and an I/O error occurs on a RAID device. (bug #363121) .LI Fail over to an alternate controller on a dual controller SGI RAID device only works on lun 0. Luns other than 0 were not properly switched over to the alternate path. (bug #370878) .LE