lora-car/libopencm3/scripts/data/lpc43xx/atimer.yaml

72 lines
1.8 KiB
YAML
Raw Normal View History

!!omap
- ATIMER_DOWNCOUNTER:
fields: !!omap
- CVAL:
access: rw
description: When equal to zero an interrupt is raised
lsb: 0
reset_value: '0'
width: 16
- ATIMER_PRESET:
fields: !!omap
- PRESETVAL:
access: rw
description: Value loaded in DOWNCOUNTER when DOWNCOUNTER equals zero
lsb: 0
reset_value: '0'
width: 16
- ATIMER_CLR_EN:
fields: !!omap
- CLR_EN:
access: w
description: Writing a 1 to this bit clears the interrupt enable bit in the
ENABLE register
lsb: 0
reset_value: '0'
width: 1
- ATIMER_SET_EN:
fields: !!omap
- SET_EN:
access: w
description: Writing a 1 to this bit sets the interrupt enable bit in the
ENABLE register
lsb: 0
reset_value: '0'
width: 1
- ATIMER_STATUS:
fields: !!omap
- STAT:
access: r
description: A 1 in this bit shows that the STATUS interrupt has been raised
lsb: 0
reset_value: '0'
width: 1
- ATIMER_ENABLE:
fields: !!omap
- ENA:
access: r
description: A 1 in this bit shows that the STATUS interrupt has been enabled
and that the STATUS interrupt request signal is asserted when STAT = 1 in
the STATUS register
lsb: 0
reset_value: '0'
width: 1
- ATIMER_CLR_STAT:
fields: !!omap
- CSTAT:
access: w
description: Writing a 1 to this bit clears the STATUS interrupt bit in the
STATUS register
lsb: 0
reset_value: '0'
width: 1
- ATIMER_SET_STAT:
fields: !!omap
- SSTAT:
access: w
description: Writing a 1 to this bit sets the STATUS interrupt bit in the
STATUS register
lsb: 0
reset_value: '0'
width: 1