arti f1dc5e7f6e udpstream: reboot is 1-in-2 on the real unit, not a working hand-back
Attempt 1 (16:58:45) came back: port 771 reopened at 88 s, the unit pinged,
and a VRAM screenshot showed the Terminal Manager.  Attempt 2 (17:04:15,
after a power cycle) never came back -- no ping, no rdebug at 130 s, monitor
asleep, operator reports it stuck.

The previous commit recorded attempt 1 as "it works, no power cycle needed".
That was a single sample and attempt 2 falsified it.  Section 72.3 now records
both runs as a table, the 1-of-2 rate, and the two corrections made on the way
(first "hung", then "works").

Untested hypothesis: the reset path does not reset the LANCE, and the payload
hands over with bus-master DMA enabled; an in-flight transfer or pending
interrupt may leave the board-window handshake at 0xC00000B0/0xC0000100
waiting forever.  The single-variable test would be CSR0_STOP before the jump.

vtcmd.py reboot requires --force again and states the measured rate.