TWO ROUTES TESTED: slot 11 as a class-3 bind, and a second allocator for the
op-1 object.  Both negative, with reasons.

1) SLOT 11 as bind.  slot 11 requires exactly 3 words = 2 payload ids.
   (0x667CE SUBK 0x3 ; JREQ).  It performs TWO lookups (0x667EC and 0x66810,
   both CALLA 0x7EA6FA0) before calling the bind helper.

   Earlier attempts used a fresh id as the second operand, which was invalid.
   This run used TWO EXISTING class-2 resources:

     A=0040C000  id=0040C000 class=2 w=64 h=64 b36=00000000 b40=00000000
     B=0040D000  id=0040D000 class=2 w=64 h=64 b36=00000000 b40=00000000

     slot11 [A,B] -> ERR14 (BadIDChoice)
     slot11 [B,A] -> ERR14 (BadIDChoice)

     after:  A unchanged, B unchanged (both still class 2, b40 = 0)
     query A: REPLY   query B: REPLY
     put A: ERR10     put B: ERR10

   So slot 11 rejects even two valid, queryable resources.  The lookups it does
   are typed: call #1 pushes the literal 0xffff, call #2 pushes 0
   (0x667E2 SUB A7,A7 ; 0x667E4 MOVE A7,*A14+).  Neither class-2 resource
   satisfies those types, so slot 11 is not the class-3 bind: its operand types
   are fixed by the handler and are not carried in the request.

2) SECOND ALLOCATOR for the op-1 object.  If a second allocator registered the
   class-3 object's id, the id would appear somewhere near it.

     create op=1  C=0040E000  object=003FD110
       id@0=00000000  class=3  w=64  h=64  b36=00000000  b40=00383950
     ID 0040E000 found near the object: NOWHERE within +/-0x4000 (32 KiB
     scanned in 0x400 blocks, centred on the object)

   So the op-1 object is not registered anywhere near itself.  Combined with the
   earlier full-object scan (id absent from its first 0x100 bytes), the class-3
   object carries no id at all, in any location found so far.

3) Side observation that constrains the next step: PUT_TILE's lookup is typed
   too (slot 19 pushes MOVK 0x3 immediately before the lookup), and a
   class-2 resource that is present and queryable still yields BadMatch.  So the
   gate is the lookup TYPE/CLASS match, not mere existence -- and the type is
   carried inside the handler, not in the request fields tried so far.

NEXT LEVER (not yet tried): element+0x28 is the field export treats as the
source image (0x1B238 MOVE *A5(0x28),*A11(0x610)); it is 0 at export time.
A write watchpoint on element+0x28 across create/arm1/arm2 would show whether
any slot-20 field sets it (i.e. whether the source is supplied by EXECUTE