diff --git a/prod/doc/index.html b/prod/doc/index.html index ca0b826..a3a636c 100644 --- a/prod/doc/index.html +++ b/prod/doc/index.html @@ -68,7 +68,8 @@ Defective devices can be discarded or retained for a deeper analysis.
+The crystal used in atben and atusb has a nominal tolerance +of +/- 15 ppm at 22-28 C. Low-cost oscilloscopes typically have a timing +accuracy of ++/- 100 ppm, which means that only major excursions can be detected by +measuring the clock output with such an instrument. Full-speed USB only +requires an accuracy of +/- 2500 ppm. +We can therefore consider all results within a range of +/- 1000 ppm as +sufficient, and perform more precise measurements by other means. This +applies to atben as well as to atusb. +
+ + +
+atrf-txrx -d net:ben -C 1 ++This configures atben as a promiscuous receiver. The reception +of any IEEE 802.15.4 frame or pressing Ctrl-C will terminate the command. +
+
Clock | Action + |
---|---|
0 Hz | Check voltages; check that the clock is enabled; + check for shorts around crystal; check connectivity of crystal + |
0.999-1.001 MHz, ~3.3 Vpp | Perform precision measurement with + atrf-xtal + |
Other | Check voltages; check for contamination around crystal + |
+ + +
+
Clock | Action + |
---|---|
0 Hz | Check voltages; check for shorts around crystal; check + connectivity of crystal + |
0.999-1.001 MHz, ~3.3 Vpp | Check presence of firmware; check for + shorts on SPI signals; check connectivity of SPI signals + |
7.992-8.008 MHz, ~3.3 Vpp | Perform precision measurement with + atrf-xtal + |
Other | Check voltages; check for contamination around crystal + |