diff --git a/prod/doc/analysis.html b/prod/doc/analysis.html index c16e5a4..4fd5e15 100644 --- a/prod/doc/analysis.html +++ b/prod/doc/analysis.html @@ -79,9 +79,22 @@ can be checked. If they are correct, proceed with checking the clock.
+
Domain | Voltage | Component + |
---|---|---|
I/O | 3.3 V | C3, C6 + |
Digital | 1.8 V | C5 + |
Analog | 1.8 V | C4 + |
+Ground can be accessed at the cover of the crystal. +Note that the fiducials are not connected to ground. +
+This image shows the location of the measurement points:
@@ -89,9 +102,24 @@ can be checked. If they are correct, proceed with checking the clock.
+
Domain | Voltage | Component + |
---|---|---|
USB | 5.0 V | C1 + |
I/O | 3.3 V | C2, C10, C13 + |
Digital | 1.8 V | C12 + |
Analog | 1.8 V | C11 + |
+Ground can be accessed at the cover of the crystal, at the shield of the +USB connector, or at the test point P11. +Note that the fiducials are not connected to ground. +
+This image shows the location of the measurement points:
@@ -207,7 +235,7 @@ be good atben board on the same Ben at a comparable temperature. Up: Production and testing Prev: Functional test