mirror of
git://projects.qi-hardware.com/ben-wpan.git
synced 2024-11-26 00:39:20 +02:00
atrf/ecn/ecn0002.txt: added measurements after making boards use 12 pF and
cleaning up the soldering.
This commit is contained in:
parent
85ab2c41d5
commit
fe8bdac37f
@ -23,6 +23,8 @@ Board Error Meas. accuracy C14/C15 Trim
|
|||||||
- 14 100.0 15 0
|
- 14 100.0 15 0
|
||||||
+ 11 99.9 12 0
|
+ 11 99.9 12 0
|
||||||
+ 11 99.6 12 0
|
+ 11 99.6 12 0
|
||||||
|
(cleanup) + 14 100.0 12 0
|
||||||
|
+ 14 100.0 12 0
|
||||||
|
|
||||||
1, "red" +263 99.7 NC 0
|
1, "red" +263 99.7 NC 0
|
||||||
+263 100.0 NC 0
|
+263 100.0 NC 0
|
||||||
@ -32,6 +34,8 @@ Board Error Meas. accuracy C14/C15 Trim
|
|||||||
+ 24 100.0 10 0
|
+ 24 100.0 10 0
|
||||||
- 9 99.7 10 4.5
|
- 9 99.7 10 4.5
|
||||||
- 9 100.0 10 4.5
|
- 9 100.0 10 4.5
|
||||||
|
(cleanup) + 14 100.0 12 0
|
||||||
|
+ 14 100.0 12 0
|
||||||
|
|
||||||
(Multiple measurements to assess CNTR performance and drift. Note that
|
(Multiple measurements to assess CNTR performance and drift. Note that
|
||||||
CNTR measurements are repeatable within 1 ppm, so the nominal accuracy
|
CNTR measurements are repeatable within 1 ppm, so the nominal accuracy
|
||||||
|
Loading…
Reference in New Issue
Block a user