Production and testing: Fault analysis

Component placement and orientation

Supply voltages

Clock frequency

The flawless performance of the crystal oscillator is crucial for operation. Anomalies are easy to detect with even a low-cost oscilloscope and pinpoint specific problems and help to select further analysis steps.

The crystal used in atben and atusb has a nominal tolerance of +/- 15 ppm at 22-28 C. Low-cost oscilloscopes typically have a timing accuracy of +/- 100 ppm, which means that only major excursions can be detected by measuring the clock output with such an instrument. Full-speed USB only requires an accuracy of +/- 2500 ppm. We can therefore consider all results within a range of +/- 1000 ppm as sufficient, and perform more precise measurements by other means. This applies to atben as well as to atusb.

Measuring the clock on atben

atben normally does not output a clock signal. A 1 MHz clock can be enabled with the following command:
atrf-txrx -d net:ben -C 1
This configures atben as a promiscuous receiver. The reception of any IEEE 802.15.4 frame or pressing Ctrl-C will terminate the command.

ClockAction
0 HzCheck voltages; check that the clock is enabled; check for shorts around crystal; check connectivity of crystal
0.999-1.001 MHz, ~3.3 VppPerform precision measurement with atrf-xtal
OtherCheck voltages; check for contamination around crystal

Measuring the clock on atusb

The transceiver provides the clock for the microcontroller in atusb. A clock signal is therefore always available. Immediately after reset, the transceiver generates a 1 MHz clock. When the microcontrolled comes out of reset, it raises the transceiver's clock output to 8 MHz and then enables USB.

ClockAction
0 HzCheck voltages; check for shorts around crystal; check connectivity of crystal
0.999-1.001 MHz, ~3.3 VppCheck presence of firmware; check for shorts on SPI signals; check connectivity of SPI signals
7.992-8.008 MHz, ~3.3 VppPerform precision measurement with atrf-xtal
OtherCheck voltages; check for contamination around crystal

Precision measurements


Last update: 2011-05-18  Werner Almesberger