1
0
mirror of git://projects.qi-hardware.com/ben-wpan.git synced 2024-12-23 18:16:26 +02:00
ben-wpan/usrp
2011-03-07 04:45:15 -03:00
..
20100925-msgs usrp/: move first "step" runs to directory usrp/step/ 2010-11-12 11:44:51 -03:00
sps usrp/sps/20110306: examine sidebands ("spikes") and try to reduce them 2011-03-07 04:45:15 -03:00
avg.c usrp/: gave tools slightly more self-explaining names 2010-11-12 11:56:12 -03:00
doall usrp/doall: usage and allow passing of arguments to evscan as well 2010-12-01 11:08:41 -03:00
evscan usrp: adjust outlier rejection and signal range for improved antennas 2010-12-01 23:57:15 -03:00
fft.c usrp/fft.c (do_fft): don't output the sample number when dumping 2011-03-03 17:52:00 -03:00
fscan usrp/fscan: results are now quite stable, so 20 instead of 100 runs are enough 2010-12-01 23:37:34 -03:00
Makefile usrp/fft: one more analysis tool for antenna measurements 2010-11-16 20:28:03 -03:00
peak.c usrp/: gave tools slightly more self-explaining names 2010-11-12 11:56:12 -03:00
plpk usrp/: gave tools slightly more self-explaining names 2010-11-12 11:56:12 -03:00
plscan usrp/plscan: comment out yrange (the experiments now cover all sorts of ranges) 2011-01-03 23:09:32 -03:00
range usrp/range: more useful diagnostic output and harden against underflows 2010-12-01 11:08:41 -03:00
README usrp/README: change threshold to avoid making section reference look like a typo 2010-12-01 10:30:02 -03:00

Antenna measurements
====================

The objective of antenna measurements is to determine how much energy the
antenna transfers at different frequencies. For this, we set up a sender,
a receiver, connect one to the antennas being tested, and the other to an
arbitrarily chosen lab antenna.

Since none of the items (sender, receiver, lab antenna) are calibrated,
we can only compare antennas but we cannot determine any absolute
characteristics.


Preparing a measurement run
---------------------------

Before measuring the characteristics of an antenna, we need to set up the
test environment and obtain a number of filtering parameters. The filters
are used to reduce the effect of noise on the measurements and to suppress
contamination from other sources.

1) Install transmitter and receiver. The transmitter is an atusb or atusd
   board, the receiver an USRP2+XCVR2450 with the antenna to test.

   (The same setup may also work with a USRP1 or UN210, and a RFX2400
   board.)

   Both should be spaced at least twenty times the wavelength (12.5 cm at
   2405 MHz), or 2.5 m apart. For test runs that can be compared with each
   other, antenna placement and orientation have to be exactly the same.

   The sender runs tools/atrf-txrx/atrf-txrx, the receiver runs utilities
   from gnuradio.

2) Obtain baseline performance values. For example, activate the sender
   with

   atrf-txrx -f 2455 -p 0.5 -T +0.5

   Emit a constant wave at 2455+0.5 MHz with a power of 0.5 dBm or 1.1 mW.

   Monitor the received signal with

   usrp2_fft.py -f 2455.5M -d 16

   Record the range in which the frequency peak falls. Variations of a few
   dB are to be expected.

3) Generate a series of sample for a specific setting.

   Example:

   The following script sets up the transmitter, lets it "warm up" for ten
   seconds, then takes 100 measurements, stored in files tmp00 through
   tmp99 in a directory $PWD/100/.

   In this setup, the receiver's gnuradio runs on a different host than
   the sender. Therefore we use ssh and pass the directory from $PWD.

    atrf-txrx -f 2455 -p 2.6 -T +0.5 \
      'sleep 10;
       for a in 0 1 2 3 4 5 6 7 8 9; do
         for b in 0 1 2 3 4 5 6 7 8 9; do
           ssh ws usrp2_rx_cfile.py -d 16 -f 2455.5M -g 46 -N 1124 \
	     '$PWD'/100/tmp$a$b
         done
       done'

   Each measurement obtains 1124 samples, 1024 samples for the FFT and
   100 samples to cut off (see below).

4) Determine the shape of the captured waves in the time domain, e.g.,
   with

   gnuplot
   gnuplot> plot "<./avg 1 <100/tmp00" with lines

   "avg" outputs the magnitude of the recorded wave, averaging over the
   specified number of sample.

   Some waves will probably show a peak in the first few samples. We need
   to cut off these peaks in the later processing steps. In this example,
   we will skip the first 100 samples.

   Besides the initial peak, the waves should be of comparable amplitude.

5) Verify the distribution in the frequency domain and determine the noise
   floor.

   gnuplot> plot "<./fft -s 100 -d <100/tmp00" with lines
                             ^
                          skip initial peak

   The spectrum should be U-shaped, with narrow peaks tens of dB above
   the noise floor near the beginning and the end. Note that the noise
   floor is curved and not perfectly flat.

   From this, we pick level of the noise floor. The value should be at or
   slightly below the highest peaks of the noise between the large peaks
   at the end of the spectrum.

   This noise floor value is used to filter uninteresting samples later
   on, removing a constant bias from the results.

   In this example, we'll use a noise floor value of -60 dB.

6) Determine the "interesting" frequency range. For this, we consider all
   the spectra of the measurements:

   gnuplot> plot "<for n in 100/tmp*; do ./fft -s 100 -d <$n;echo;done" \
     with lines

   There should be a thick noise band in the middle, with pronounced
   narrow peaks at the edges. If there are one or two signals on top of
   the noise band, some measurements have been compromised and need to be
   removed or redone. We will do this in the next step.

   When zooming into the left peak, the "bins" which contribute to the
   peaks can be identified. The range should be chosen with some
   tolerance, since the frequency may shift a bit during the measurement
   process.

   By not considering bins far from the peak, less noise is included in
   the final result, complementing the filtering by noise threshold from
   step 4). Restricting the bins also eliminates the second peak at the
   end of the spectrum.

   In this example, we'll use a range from 0 to 20.

7) Obtain the peaks from all measurements

   gnuplot> plot "<for n in 100/tmp*; do ./fft -s 100 0 20 60 <$n;done" \
     with lines
                                                   ^  ^  ^ ^
                                                   |  |  | |
                                   skip, from step 4  |  | threshold, 5)
                                             lowest bin  highest bin

   This should yield a jagged more or less horizontal line with values
   differing by not more than 1-2 dB. If there are any large outliers,
   they have been contaminated and should be dropped.

8) The final result for one measurement run can be obtained as follows:

   for n in 100/tmp*; do ./fft -s 100 0 20 60 <$n;done | ./range -v 2

   In this example, "range" eliminates all outliers more than 2 dB from
   the average and reports this.

   The output are three numbers: the average (after eliminating
   outliers), the minimum, and the maximum.


Performing a measurement run
----------------------------

The script "fscan" performs 100 scans of the 26 channels used by IEEE
802.15.4. The frequency scan is the inner loop, so that slow changes
in environmental parameters (background noise, temperature, etc.) will
affect the spread of the results over the entire frequency range instead
of causing seemingly frequency-dependent distortions.

The script is written for a setup that uses a pair of hosts, both
sharing the same file system.

Usage: fscan out-dir [tx-power]

The output directory must not exist yet. The transmit power is in dBm and
defaults to 2.6 dBm.

Example: ./fscan testant

The full run takes approximately half an hour.

The results are filtered and averaged by the script "evscan". This script
contains the filtering parameters obtained in the preparation, described
above.

Example: ./evscan testant >testant.out

The output is a graph with frequency, average signal strength, minimum
and maximum. The format is compatible with gnuplot's "with errorbars"
(or "with errorlines") plot style.

Finally, the results can be plotted with the script "plscan", which uses
gnuplot to output either in a window or to a PNG file.

Usage: plscan [-o pngfile] file ...

More than one graph can be plotted in the same run. The file name is used
as the title for each graph. Titles are truncated at the last dot.

Example: ./plscan testant.out