Werner Almesberger 2e742d9281 Assorted termination simulation cleanup.
- term/Makefile: "make qucs" shortcut for invoking qucs
- term/term.sch: disable switch to .dpl page after simulation
- term/term.sch: changed R3 from 50 Ohm to the more common 47 Ohm
- term/term.sch: changed C2 from 22 pF to 330 pF to match TVS
- term/term.sch: renamed Vin to Vdst and put graph in diagram on top
- term/term.sch: added more annotations
2010-10-24 20:15:11 -03:00
..
fw Made communication with CNTR board more robust. Added documentation. 2010-08-25 18:47:45 -03:00
term Assorted termination simulation cleanup. 2010-10-24 20:15:11 -03:00
tools Picking time in the middle of the interval, not its edge, and reduce 2010-08-26 00:52:50 -03:00
cntr.brd Added title, author, and revision to all schematics and layouts. 2010-08-25 19:42:46 -03:00
cntr.pro The parasitic capacitance of the three probe input pins and R1 formed a 2010-08-25 06:36:02 -03:00
cntr.sch Cleaned up component values in cntr schematics. 2010-10-24 19:43:53 -03:00
Makefile Forgot cntr/Makefile. Added ground fill. 2010-08-22 21:45:25 -03:00
README Made communication with CNTR board more robust. Added documentation. 2010-08-25 18:47:45 -03:00

Arbitrary-precision counter
===========================

Theory of operation
-------------------

The arbitrary-precision counter counts clock cycles of a frequency
source that is assumed to be free from drift. It compares the count
with the host's system clock. If the system clock is synchronized with
an accurate NTP reference, measurements with arbitrarily high accuracy
can be obtained.

In practice, this is limited by the the frequency source's drift and
the time one is willing to wait. If NTP maintains the system time
with an accuracy of +/- 100 ms, obtaining measurements with an
accuracy of +/- 1 ppm would take about 28 hours.

Additional error sources, such as the round-trip time when requesting
a sample from the microcontroller, are also considered in the accuracy
calculation.

The counter consists of a board based on a C8051F320 microcontroller
and the control software on the host. The microcontroller counts
events in a free-running 16 bit counter that is regularly read and
extended to 32 bits. The 32 bit counter is periodically queried by
the host.

The microcontroller's counter can count at a frequency of up to 3 MHz.
(SYSCLK/4)

In order to protect against transmission errors not detected by USB's
CRC, which are occur relatively often, each packet is protected by a
CRC-32 and an inverted copy of the payload. Corrupted packets are
rejected by the host.

The 32 bit counter wraps around at most once very 21.8 ms. The 32 bit
counter wraps around at most every 1431 s. The host extends the 32 bit
counter to 64 bits, and calculates frequency and accuracy from the
count and the run time of the measurement application.


Performing a measurement
------------------------

To perform a measurement, connect the CNTR board's probe input to the
clock source and then run the "cntr" application on the host. An
accuracy goal (in ppm) can be specified on the command line (see
below).

The host polls the microcontroller every 100 ms and displays the run
time (in seconds), the measured frequency, and the accuracy achieved
so far.

Measurements can be stopped by pressing ^C or by specifying an
accuracy goal. At the end, the total number of events counted and
communication statistics are displayed.


Updating the firmware
---------------------

The protocol revision and the build date of the firmware of the CNTR
board can be queried with "cntr -i".

To update the firmware, run
cntr -r && sleep 1 && dfu-util -d 0x20b7:0xcb72 -D cntr.bin