From b864df85ddb7500bacaa7f1764f3254e0177f106 Mon Sep 17 00:00:00 2001 From: Adam Wang Date: Wed, 4 Apr 2012 08:42:09 +0800 Subject: [PATCH] correcting NC pins to Unspecified electrical type. --- components/xc6slx45-2fgg484c.dcm | 2 +- components/xc6slx45-2fgg484c.lib | 52 ++++++++++++++++---------------- 2 files changed, 27 insertions(+), 27 deletions(-) diff --git a/components/xc6slx45-2fgg484c.dcm b/components/xc6slx45-2fgg484c.dcm index 7dfbc67..5b1a354 100644 --- a/components/xc6slx45-2fgg484c.dcm +++ b/components/xc6slx45-2fgg484c.dcm @@ -1,4 +1,4 @@ -EESchema-DOCLIB Version 2.0 Date: Tue 03 Apr 2012 20:47:18 CST +EESchema-DOCLIB Version 2.0 Date: Wed 04 Apr 2012 08:41:14 CST # $CMP XC6SLX45-2FGG484C D XC6SLX45-2FGG484C, SPARTAN-6 diff --git a/components/xc6slx45-2fgg484c.lib b/components/xc6slx45-2fgg484c.lib index 61c1896..d528830 100644 --- a/components/xc6slx45-2fgg484c.lib +++ b/components/xc6slx45-2fgg484c.lib @@ -1,4 +1,4 @@ -EESchema-LIBRARY Version 2.3 Date: Tue 03 Apr 2012 20:47:18 CST +EESchema-LIBRARY Version 2.3 Date: Wed 04 Apr 2012 08:41:14 CST # # XC6SLX45-2FGG484C # @@ -386,15 +386,15 @@ X GND E7 -1400 -2350 300 R 50 50 5 1 W X GND H7 -1400 -2650 300 R 50 50 5 1 W X GND U7 -1400 250 300 R 50 50 5 1 W X GND W7 -1400 -350 300 R 50 50 5 1 W -X NC E8 1400 -1150 300 L 50 50 5 1 I -X NC F8 1400 -1750 300 L 50 50 5 1 I -X NC G8 1400 -2150 300 L 50 50 5 1 I +X NC E8 1400 -1150 300 L 50 50 5 1 U +X NC F8 1400 -1750 300 L 50 50 5 1 U +X NC G8 1400 -2150 300 L 50 50 5 1 U X VCCINT J8 1400 1150 300 L 50 50 5 1 W X VCCAUX L8 1400 2350 300 L 50 50 5 1 W X VCCAUX N8 1400 2150 300 L 50 50 5 1 W X GND B9 -1400 -1650 300 R 50 50 5 1 W -X NC F9 1400 -1850 300 L 50 50 5 1 I -X NC G9 1400 -2250 300 L 50 50 5 1 I +X NC F9 1400 -1850 300 L 50 50 5 1 U +X NC G9 1400 -2250 300 L 50 50 5 1 U X VCCAUX H9 1400 2550 300 L 50 50 5 1 W X GND J9 -1400 2750 300 R 50 50 5 1 W X VCCINT K9 1400 850 300 L 50 50 5 1 W @@ -402,9 +402,9 @@ X GND L9 -1400 1950 300 R 50 50 5 1 W X VCCINT M9 1400 250 300 L 50 50 5 1 W X GND N9 -1400 1050 300 R 50 50 5 1 W X VCCINT P9 1400 -350 300 L 50 50 5 1 W -X NC E10 1400 -850 300 L 50 50 5 1 I -X NC F10 1400 -1250 300 L 50 50 5 1 I -X NC H10 1400 -2350 300 L 50 50 5 1 I +X NC E10 1400 -850 300 L 50 50 5 1 U +X NC F10 1400 -1250 300 L 50 50 5 1 U +X NC H10 1400 -2350 300 L 50 50 5 1 U X VCCINT J10 1400 1450 300 L 50 50 5 1 W X GND K10 -1400 2650 300 R 50 50 5 1 W X VCCINT L10 1400 750 300 L 50 50 5 1 W @@ -415,8 +415,8 @@ X VCCAUX R10 1400 2050 300 L 50 50 5 1 W X GND V10 -1400 150 300 R 50 50 5 1 W X GND E11 -1400 -1950 300 R 50 50 5 1 W X VCCAUX F11 1400 2850 300 L 50 50 5 1 W -X NC G11 1400 -1950 300 L 50 50 5 1 I -X NC H11 1400 -2450 300 L 50 50 5 1 I +X NC G11 1400 -1950 300 L 50 50 5 1 U +X NC H11 1400 -2450 300 L 50 50 5 1 U X GND J11 -1400 -2750 300 R 50 50 5 1 W X VCCINT K11 1400 1050 300 L 50 50 5 1 W X GND L11 -1400 2350 300 R 50 50 5 1 W @@ -429,11 +429,11 @@ X GND J21 -1400 2850 300 R 50 50 5 1 W X GND N21 -1400 1150 300 R 50 50 5 1 W X GND U21 -1400 350 300 R 50 50 5 1 W X GND AB1 -1400 -1150 300 R 50 50 5 1 W -X NC D12 1400 -650 300 L 50 50 5 1 I -X NC E12 1400 -950 300 L 50 50 5 1 I -X NC F12 1400 -1350 300 L 50 50 5 1 I +X NC D12 1400 -650 300 L 50 50 5 1 U +X NC E12 1400 -950 300 L 50 50 5 1 U +X NC F12 1400 -1350 300 L 50 50 5 1 U X VCCAUX G12 1400 2750 300 L 50 50 5 1 W -X NC H12 1400 -2550 300 L 50 50 5 1 I +X NC H12 1400 -2550 300 L 50 50 5 1 U X VCCINT J12 1400 1350 300 L 50 50 5 1 W X GND K12 -1400 2550 300 R 50 50 5 1 W X VCCINT L12 1400 650 300 L 50 50 5 1 W @@ -443,19 +443,19 @@ X GND P12 -1400 850 300 R 50 50 5 1 W X VCCAUX R12 1400 1950 300 L 50 50 5 1 W X GND A22 -1400 -650 300 R 50 50 5 1 W X GND B13 -1400 -1350 300 R 50 50 5 1 W -X NC D13 1400 -750 300 L 50 50 5 1 I -X NC F13 1400 -1450 300 L 50 50 5 1 I -X NC G13 1400 -2050 300 L 50 50 5 1 I -X NC H13 1400 -2650 300 L 50 50 5 1 I +X NC D13 1400 -750 300 L 50 50 5 1 U +X NC F13 1400 -1450 300 L 50 50 5 1 U +X NC G13 1400 -2050 300 L 50 50 5 1 U +X NC H13 1400 -2650 300 L 50 50 5 1 U X GND J13 -1400 -2850 300 R 50 50 5 1 W X VCCINT K13 1400 950 300 L 50 50 5 1 W X GND L13 -1400 2250 300 R 50 50 5 1 W X VCCINT M13 1400 350 300 L 50 50 5 1 W X GND N13 -1400 1450 300 R 50 50 5 1 W X VCCINT P13 1400 -250 300 L 50 50 5 1 W -X NC E14 1400 -1050 300 L 50 50 5 1 I -X NC F14 1400 -1550 300 L 50 50 5 1 I -X NC H14 1400 -2750 300 L 50 50 5 1 I +X NC E14 1400 -1050 300 L 50 50 5 1 U +X NC F14 1400 -1550 300 L 50 50 5 1 U +X NC H14 1400 -2750 300 L 50 50 5 1 U X VCCINT J14 1400 1250 300 L 50 50 5 1 W X GND K14 -1400 2450 300 R 50 50 5 1 W X VCCINT L14 1400 550 300 L 50 50 5 1 W @@ -465,19 +465,19 @@ X GND P14 -1400 750 300 R 50 50 5 1 W X VCCINT R14 1400 -450 300 L 50 50 5 1 W X GND V14 -1400 50 300 R 50 50 5 1 W X GND E15 -1400 -2050 300 R 50 50 5 1 W -X NC F15 1400 -1650 300 L 50 50 5 1 I +X NC F15 1400 -1650 300 L 50 50 5 1 U X VCCAUX H15 1400 2650 300 L 50 50 5 1 W X GND J15 -1400 -2950 300 R 50 50 5 1 W X VCCAUX K15 1400 2450 300 L 50 50 5 1 W X VCCAUX M15 1400 2250 300 L 50 50 5 1 W -X NC P15 1400 -3050 300 L 50 50 5 1 I +X NC P15 1400 -3050 300 L 50 50 5 1 U X GND AA5 -1400 -950 300 R 50 50 5 1 W X VCCAUX D16 1400 2950 300 L 50 50 5 1 W -X NC P16 1400 -2850 300 L 50 50 5 1 I +X NC P16 1400 -2850 300 L 50 50 5 1 U X GND W16 -1400 -150 300 R 50 50 5 1 W X GND B17 -1400 -1450 300 R 50 50 5 1 W X GND N17 -1400 1350 300 R 50 50 5 1 W -X NC R17 1400 -2950 300 L 50 50 5 1 I +X NC R17 1400 -2950 300 L 50 50 5 1 U X GND D18 -1400 -1750 300 R 50 50 5 1 W X GND G18 -1400 -2450 300 R 50 50 5 1 W X GND L18 -1400 2150 300 R 50 50 5 1 W