mirror of
git://projects.qi-hardware.com/wernermisc.git
synced 2024-11-15 11:50:37 +02:00
labsw/LOG: reworked power supply bypassing
This commit is contained in:
parent
a42bf17291
commit
05c52e7390
35
labsw/LOG
35
labsw/LOG
@ -150,6 +150,28 @@ Milled face plate #3:
|
|||||||
LEDs to the pull-ups. Work-around: add 10 kOhm in parallel to each
|
LEDs to the pull-ups. Work-around: add 10 kOhm in parallel to each
|
||||||
LED.
|
LED.
|
||||||
|
|
||||||
|
--- Wed 2011-09-07 ------------------------------------------------------------
|
||||||
|
|
||||||
|
Rework:
|
||||||
|
- problem: labsw occasionally (around 1% of all cycles in an automated
|
||||||
|
test loop) gets some configuration bits wrong. The pattern observed
|
||||||
|
so far is that, in an attempt to turn on CH1, then CH2, CH1 comes on
|
||||||
|
normally while CH2 either doesn't come on at all or the relay switches
|
||||||
|
but the LED doesn't.
|
||||||
|
- analysis:
|
||||||
|
This may be a problem with the power supply or with USB. Consider
|
||||||
|
some or all of the following improvements:
|
||||||
|
|
||||||
|
- follow SiLab's recommendations for regulator bypassing more closely
|
||||||
|
- enable the VDD monitor to catch brown-outs
|
||||||
|
- add ground areas to shield CPU and USB
|
||||||
|
- add redundancy to EP0 protocol
|
||||||
|
- add bead to relay power, to prevent upsetting the 5 V rail
|
||||||
|
- rework:
|
||||||
|
Implemented power supply bypassing according to SiLabs' recommendations:
|
||||||
|
- added 4.7 uF in parallel to C1
|
||||||
|
- added 100 nF in parallel to C2
|
||||||
|
|
||||||
---------------------
|
---------------------
|
||||||
|
|
||||||
(next PCB run)
|
(next PCB run)
|
||||||
@ -174,16 +196,3 @@ Pending:
|
|||||||
3) drive opto LEDs from 3.3 V instead of 5 V (NOT ! Regulator
|
3) drive opto LEDs from 3.3 V instead of 5 V (NOT ! Regulator
|
||||||
can only provide 100 mA, which wouldn't be enough if more than
|
can only provide 100 mA, which wouldn't be enough if more than
|
||||||
two opto-couplers are active.)
|
two opto-couplers are active.)
|
||||||
- labsw occasionally gets some configuration bits wrong. The pattern
|
|
||||||
observed so far it that, in an attempt to turn on CH1, then CH2, CH1
|
|
||||||
comes on normally while CH2 either doesn't come on at all or the
|
|
||||||
relay switches but the LED doesn't.
|
|
||||||
|
|
||||||
This may be a problem with the power supply or with USB. Consider
|
|
||||||
some or all of the following improvements:
|
|
||||||
|
|
||||||
- follow SiLab's recommendations for regulator bypassing more closely
|
|
||||||
- enable the VDD monitor to catch brown-outs
|
|
||||||
- add ground areas to shield CPU and USB
|
|
||||||
- add redundancy to EP0 protocol
|
|
||||||
- add bead to relay power, to prevent upsetting the 5 V rail
|
|
||||||
|
Loading…