* *#ident "@(#)sccs:help.d/cm 6.3"
|
|
*#ident "%W%"
|
|
* Messages common to more than one SCCS command.
|
|
*
|
|
-1
|
|
"unknown key letter"
|
|
You supplied a keyletter which the command does not recognize.
|
|
-2
|
|
"key letter twice"
|
|
You supplied a keyletter more than once.
|
|
-3
|
|
"missing file arg"
|
|
You left off the name of the file to be processed.
|
|
-4
|
|
"cannot create lock file"
|
|
There are two known reasons why this can occur.
|
|
|
|
1) Someone else is updating the SCCS file (or the p-file).
|
|
You'll have to wait until they're through, and try again.
|
|
|
|
2) You do not have write permission in the directory where the
|
|
SCCS file resides. If this is so, you are not allowed to
|
|
create any files (including the ``lock file'') in that
|
|
directory.
|
|
|
|
If it is neither of the two reasons and the problem persists, contact
|
|
your Source Code Administrator (SCA).
|
|
-5
|
|
"bad date/time"
|
|
The date/time must be a legitimate date/time in the form
|
|
"YY[MM[DD[HH[MM[SS]]]]]". The program knows about things
|
|
like leap years, so be precise.
|
|
-6
|
|
"no id keywords"
|
|
No SCCS identification keywords were substituted for (or found).
|
|
If this message came from delta then you just tryed to make a
|
|
delta without any keywords.
|
|
|
|
If this message came from get then
|
|
your source code administrator blew it.
|
|
Complain to him/her.
|
|
|
|
If this message came from admin,
|
|
you blew it.
|
|
-7
|
|
"No id keywords"
|
|
No SCCS identification keywords were substituted for.
|
|
You may not have any keywords in the file,
|
|
in which case you can ignore this warning.
|
|
If this message came from delta then you just made a
|
|
delta without any keywords.
|
|
If this message came from get then
|
|
the last time you made a delta you changed the lines
|
|
on which they appeared.
|
|
It's a little late to be
|
|
telling you that you messed up the last time you made a delta, but this is
|
|
the best we can do for now, and it's better than nothing.
|
|
|
|
This isn't an error, only a warning.
|
|
-8
|
|
"value after ... arg"
|
|
You had something after the indicated keyletter argument and you weren't
|
|
supposed to.
|
|
-9
|
|
"User ID not in password file ..."
|
|
You are apparently running on a system on which you do not
|
|
have a login (via a data link of some type). SCCS will
|
|
not allow you to make changes to a file if your user ID is not
|
|
located in the password file.
|
|
-10
|
|
"invalid id keywords"
|
|
The specific id keywords specified to admin via -fi"string"
|
|
were not found in the file. You are trying to delta
|
|
a file with expanded keywords, get a file which was admin'd
|
|
to verify keywords after the last delta, or admin a new file
|
|
whose keywords do not match what was specified by "string".
|