labsw/LOG: theory that the failures to switch are caused by EMI (on buttons)
This commit is contained in:
parent
37df000637
commit
1152189acb
15
labsw/LOG
15
labsw/LOG
@ -195,6 +195,21 @@ Rework:
|
||||
- turn-on cycle: all LEDs green, no power (not a reset)
|
||||
- 5+ normal cycles
|
||||
|
||||
Further analysis: the absence of more abnormal states, such as LEDs
|
||||
contradicting relays or LEDs just going dark suggests that the problem
|
||||
is may not be USB data corruption. At least some of the symptoms would
|
||||
be compatible with EMI from switching the relay creating false signals
|
||||
on the buttons.
|
||||
|
||||
The "all LEDs green" condition would be a false press of MAIN. The
|
||||
CH2 green condition would be harder to explain. Maybe the MAIN LED
|
||||
was also green and I didn't notice. In this case, it would have been
|
||||
a combination of the MAIN and CH1 buttons (MAIN to exit remote mode,
|
||||
turn off all the channels, and enable the channel buttons. Then CH1 to
|
||||
turn on CH1 again.)
|
||||
|
||||
To do: debounce buttons (in software) before accepting a state change.
|
||||
|
||||
---------------------
|
||||
|
||||
(next PCB run)
|
||||
|
Loading…
Reference in New Issue
Block a user