m1rc3/usbpwr/README: corrected averaging: 1 PLC instead of 10 PLC

This commit is contained in:
Werner Almesberger 2011-12-22 08:54:25 -03:00
parent 017e7be93f
commit 8361bfac8b
1 changed files with 1 additions and 1 deletions

View File

@ -35,7 +35,7 @@ with current limit set to 3.0 A.
DC input.
"J21/J3" is the voltage on the internal 5 V rail measured across
J21.1 and J3.14, with a Fluke 8845A with averaging set to 10 PLC.
J21.1 and J3.14, with a Fluke 8845A with averaging set to 1 PLC.
[5] shows the measurement configuration.
"Boot" indicates whether the M1 can boot out of standby with the