@ -29,7 +29,7 @@ Voltages should be tested in the following order: USB, then I/O, then
|
||||
digital, and finally analog. The table below gives the permissible
|
||||
ranges. Any voltages outside of these ranges indicate a problem.
|
||||
<P>
|
||||
<TABLE>
|
||||
<TABLE frame="border" cellpadding="2">
|
||||
<TR><TH>Domain<TH>Nominal<TH>Minimum<TH>Maximum
|
||||
<TR><TD>USB<TD>5.0 V<TD>4.5 V<TD>5.25 V
|
||||
<TR><TD>I/O<TD>3.3 V<TD>3.0 V<TD>3.6 V
|
||||
@ -90,12 +90,12 @@ operation. Anomalies are easy to detect with even a low-cost oscilloscope
|
||||
and pinpoint specific problems and help to select further analysis steps.
|
||||
<P>
|
||||
The crystal used in <B>atben</B> and <B>atusb</B> has a nominal tolerance
|
||||
of +/- 15 ppm at 22-28 C. Low-cost oscilloscopes typically have a timing
|
||||
of +/− 15 ppm at 22-28 C. Low-cost oscilloscopes typically have a timing
|
||||
accuracy of
|
||||
+/- 100 ppm, which means that only major excursions can be detected by
|
||||
+/− 100 ppm, which means that only major excursions can be detected by
|
||||
measuring the clock output with such an instrument. Full-speed USB only
|
||||
requires an accuracy of +/- 2500 ppm.
|
||||
We can therefore consider all results within a range of +/- 1000 ppm as
|
||||
requires an accuracy of +/− 2500 ppm.
|
||||
We can therefore consider all results within a range of +/− 1000 ppm as
|
||||
sufficient, and perform more precise measurements by other means. This
|
||||
applies to <B>atben</B> as well as to <B>atusb</B>.
|
||||
<P>
|
||||
@ -114,7 +114,7 @@ atrf-txrx -d net:ben -C 1
|
||||
This configures <B>atben</B> as a promiscuous receiver. The reception
|
||||
of any IEEE 802.15.4 frame or pressing Ctrl-C will terminate the command.
|
||||
<P>
|
||||
<TABLE>
|
||||
<TABLE frame="border" cellpadding="2">
|
||||
<TR><TH align="left">Clock<TH align="left">Action
|
||||
<TR><TD>0 Hz<TD>Check voltages; check that the clock is enabled;
|
||||
check for shorts around crystal; check connectivity of crystal
|
||||
@ -136,7 +136,7 @@ the transceiver generates a 1 MHz clock. When the microcontrolled comes out
|
||||
of reset, it raises the transceiver's clock output to 8 MHz and then
|
||||
enables USB.
|
||||
<P>
|
||||
<TABLE>
|
||||
<TABLE frame="border" cellpadding="2">
|
||||
<TR><TH align="left">Clock<TH align="left">Action
|
||||
<TR><TD>0 Hz<TD>Check voltages; check for shorts around crystal; check
|
||||
connectivity of crystal
|
||||
@ -154,7 +154,7 @@ enables USB.
|
||||
<H3>Precision measurements</H3>
|
||||
|
||||
The clock frequency of <B>atben</B> can be measured with an accuracy
|
||||
of about +/- 100 ppm using the program <B>atrf-xtal</B>. <B>atrf-xtal</B>
|
||||
of about +/− 100 ppm using the program <B>atrf-xtal</B>. <B>atrf-xtal</B>
|
||||
runs directly on the Ben and measures the duration of packet transmissions.
|
||||
The transmission time depends on the bit clock which is in turn derived
|
||||
from the oscillator.
|
||||
@ -169,10 +169,10 @@ The number reported is the number of poll loops the CPU counted. This
|
||||
value should be compared to a reference count obtained with a known to
|
||||
be good <B>atben</B> board and the same Ben at a comparable temperature.
|
||||
<P>
|
||||
<TABLE>
|
||||
<TABLE frame="border" cellpadding="2">
|
||||
<TR><TH align="left">Difference<TH align="left">Action
|
||||
<TR><TD>> +/- 50 ppm<TD>Correct operation
|
||||
<TR><TD>< -80 ppm<TD>Check soldering of capacitors;
|
||||
<TR><TD>> +/− 50 ppm<TD>Correct operation
|
||||
<TR><TD>< −80 ppm<TD>Check soldering of capacitors;
|
||||
check for contamination around crystal
|
||||
<TR><TD>> +120 ppm<TD>idem
|
||||
<TR><TD>Other<TD>Divergence can be compensated by adjusting trim value
|
||||
|
Loading…